Jeff Kay – Update – Emerging Technology Focused Ultrasound in Substance Use Disorder

Focused ultrasound has been used in treatment for a number of conditions including essential tremor, Parkinson’s disease, and ablation of uterine fibroids. It differs from diagnostic ultrasound in that the beams are focused to act on tissue. In the above conditions the goal is ablation, tissue destruction without invasive surgery and is FDA approved for those conditions.

There is investigational use in lower intensity to disrupt neural activity without tissue destruction. This hold promise for conditions like substance use disorder where specific pathways are known and well documented.

Improvements in technology allow for the development of hardware able to precisely generate and steer low intensity (LUS) beams to a small focal point using imaging guidance. Studies reviewed here investigate use targeting the nucleus accumbens (NAc) a structure critical in SUD where reward, and cortical – cingulate behavioral pathways converge be coming sensitized and dysfunctional in chronic addictive substance use. Real time MRI was used for guidance during the procedure.

This could replace more invasive procedures involving surgical placement of probe wires into deep brain structures.

Ultrasound generates high frequency sound via a crystalline transducer which acts to both generate and receive reflected sound waves.

The bean attenuates as it passes through tissues of different density such as fluid, solid organs, or bone. In diagnostic ultrasounds the echos bouncing back to the transducer are reassembled into an image.

Brief review of the physics involved. Sound waves are physical displacement of matter such as air, water or a solid which is alternately compressed then decompressed. The wave may vary in frequency, higher or lower pitch in audible sound, and amplitude, the energy of the beam corresponding to loudness in audible sound.

With higher energy tissue can be affected by two processes. Cavitation refers to bubble formation in liquids. Liquids contain dissolved gasses. In cavitation the force of compression followed by decompression can disrupt the forces holding molecules together in a liquid state resulting in bubbles. Think of bubbles generated underwater by submarine propellers.

With sufficient force the bubbles collapse then deform sending a pressure shockwave, heat and a fluid jet into the surrounding medium. In tissue this destroys membranes and fibers resulting in tissue destruction.

It can also generate heat due to molecular motion from imparted energy of the sound wave.

For some applications such as tumor or uterine fibroid treatment this is the desired outcome performed in a precise location and avoiding damage to surrounding tissues. For conditions such as SUD or other psychiatric conditions the goal is to avoid permanent changes using lower energy focused ultrasound (LUD) to modulate and temporarily disrupt neural transmission.

In focused ultrasound multiple low intensity beams are concentrated to a single point for a predetermined period of time. The company Insightec is a startup venture which has produced equipment incorporating an array of 1024 transducers in a cup-like configuration. By phasic changes the focal point can be steered to a very small point at 5mm or smaller resolution.

The equipment has sensors to monitor heat, and internal energy to avoid overheating and tissue damage. It is MRI compatible allowing for precise targeting of brain tissue.

Screenshot

This was a proof of concept study on 4 subjects with histories of severe opiate dependance refractory to conventional treatment. The subjects also had a history of poly substance use. The subjects underwent one treatment session each.

Outcomes were measured by subjective craving scales when presented with visual drug related cues at baseline, during, and following the procedure.

The graph depicts pretest craving for the substances listed one week prior to the procedure. One week post test craving is depicted by the blue bars. There was marked reduction in craving following the procedure of 50% or greater. There were no significant complications or adverse effects noted.

Longer term outcomes with weekly logging of subjective craving recorded for two of the subjects (subjects 3 and 4). Blue is 1 week and red is the 90 day scores. Reduction increased for all substances except nicotine in subject #3 and near absent for subject #4.

Of particular note craving reduced with no interval treatment in one of the subjects indicating improved benefit over time.

This was an open label single arm study in individuals with histories of severe opioid use disorder and poly use disorders. 16 individuals completed the study of which 8 were included in the final analysis.

The bilateral nucleus accumbens was targeted by MRI guidance. Cue induced craving and safety were primary outcomes. Craving scores along with fMRI were obtained.

Opioid craving scores were measured at baseline, immediately after, and at intervals up to 90 days post procedure. Visual drug related slides were presented by MRI compatible headsets and rated by a standardized scale from 1-10.

Results were striking with  average score decreasing from around 9 at baseline to around 1 up to 90 days after the procedure. There were no significant adverse events other than transient headache reported.

Seven subjects were abstinent through 30 days and 5 remained abstinent throughout the study.

Craving for substances other than the individual DOC were assessed for the substances listed above. The pattern is similar to results for opiates. Score less than 1 up to 90 days for all substances except nicotine which did demonstrate significant reduction.

Functional MRI was performed at baseline and intervals up to 90 days. Connectivity to the NAc was done using seed based whole brain connectivity cluster voxel analysis.

Green arrows above point to connectivity cluster in the cingulate gyrus and medial prefrontal cortex. These regions are key in addictions and govern executive function, impulse control and habit formation.

Results are striking. The scans depict early increased connectivity to these regions with subsequent decrease through 90 days.

Τhis is a case report of an adverse event which occurred in a study involving LUS in Substance use disorder. The patient was sedated and monitored during the procedure and was stable throughout. Following the procedure the patient was difficult to arouse and was non responsive to verbal stimuli for 24 hours after which the patient regained consciousness. There was difficulty in walking and mental confusion which gradually returned. At 5 months some memory deficits with intermittent confusion remained. Functionally the individual was close to baseline.

Analysis of the event demonstrated what was likely a failure of equipment monitoring parameters. The problem was addressed and additional safety measures were implemented.

Pre and post procedure diagnostic MRIs were performed on the patient from baseline to 113 days after the event. The second row red arrows point to small bright foci on FLAIR sequences. These resolve by day 113 and represent edema in the nucleus accumbens and caudate nuclei bilaterally. Gradient echo sequences showed susceptibility consistent with small petechial hemorrhages which resolved.

Focused ultrasound has become an emerging therapeutic modality and is FDA approved for use in Parkinson’s disease, essential tremor, and uterine fibroids. Use in neuropsychiatric conditions including Substance Use Disorders is a field with potential utility.

Studies presented here are small proof of concept early studies and have significant limitations. Early results are very promising. One adverse event has been reported. The remaining cases had no significant safety issues other than transient headache. There is need for more studies to prove a high level of safety as the procedure is not without risks.

There are 14 registered clinical trials proposed or underway at the present time. There is urgent need for treatment options particularly in individuals with multiple treatment failures. Further investigation of this modality is warranted.

Thank you for your interest in reading this post. Data and images are taken from sources freely available on the World Wide Web. This post should not be considered medical or professional advice.

Feedback and comments are always welcome

Jeffk072261@gmail.com

References

LIFU links

https://www.cell.com/device/pdfExtended/S2666-9986(25)00207-

https://www.brainstimjrnl.com/article/S1935-861X(25)00358-4/pdf

……………………………………………….

JAMA Neurology | Review

A Review of the Current Therapies, Challenges,

and Future Directions of Transcranial Focused

Ultrasound Technology

Advances in Diagnosis and Treatment

VibhorKrishna,MD,SM;FrancescoSammartino,MD;AliRezai,MD

https://www.researchgate.net/profile/Vibhor-Krishna/publication/321737002_A_Review_of_the_Current_Therapies_Challenges_and_Future_Directions_of_Transcranial_Focused_Ultrasound_Technology_Advances_in_Diagnosis_and_Treatment/links/5aa69e190f7e9b463804d3ac/A-Review-of-the-Current-Therapies-Challenges-and-Future-Directions-of-Transcranial-Focused-Ultrasound-Technology-Advances-in-Diagnosis-and-Treatment.pdf

…………………………………………………………………

…………………………………………………………………..

Low-intensity transcranial focused ultrasound amygdala

neuromodulation: a double-blind sham-controlled target

engagement study and unblinded single-arm clinical trial

Bryan R. Barksdale1, Lauren Enten1, Annamarie DeMarco1, Rachel Kline1, Manoj K. Doss 1, Charles B. Nemeroff 1 and Gregory A. Fonzo

Molecular Psychiatry (2025) 30:4497 – 451m

………………………………………………………………….

………………………………………………………………….

Jeff Kay 06/26